Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PTM2-3-S5-SDC-DC, ISOLATED, 2 W, 2.97~3.63 |
48 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 2.97V | 3.63V | 5V | - | - | - | 400mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 78.5% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-3-S3-SDC-DC, ISOLATED, 2 W, 2.97~3.63 |
48 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 2.97V | 3.63V | 3.3V | - | - | - | 606mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 77% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-12-S15-SDC-DC, ISOLATED, 2 W, 10.8~13.2 |
48 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 10.8V | 13.2V | 15V | - | - | - | 134mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 83% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-24-S12-SDC-DC, ISOLATED, 2 W, 21.6~26.4 |
48 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 21.6V | 26.4V | 12V | - | - | - | 167mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 85% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-5-S15-SDC-DC, ISOLATED, 2 W, 4.5~5.5 VD |
46 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 5.5V | 15V | - | - | - | 134mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 84% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-12-S12-SDC-DC, ISOLATED, 2 W, 10.8~13.2 |
46 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 10.8V | 13.2V | 12V | - | - | - | 167mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 90°C (With Derating) | 84% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-3-S12-SDC-DC, ISOLATED, 2 W, 2.97~3.63 |
43 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 2.97V | 3.63V | 12V | - | - | - | 167mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 82% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-5-S5-SDC-DC, ISOLATED, 2 W, 4.5~5.5 VD |
37 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 5.5V | 5V | - | - | - | 400mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 79% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-12-S5-SDC-DC, ISOLATED, 2 W, 10.8~13.2 |
37 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 10.8V | 13.2V | 5V | - | - | - | 400mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 80% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
PTM2-5-S3-SDC-DC, ISOLATED, 2 W, 4.5~5.5 VD |
35 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 5.5V | 3.3V | - | - | - | 606mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 77% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
RSO-0505S/H2DC DC CONVERTER 5V 1W |
32 |
|
![]() Datasheet |
ECONOLINE RSO (1W) | 8-SIP Module, 7 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 9V | 5V | - | - | - | 200mA | 1 W | 2 kV | ITE (Commercial), Medical | Remote On/Off, SCP | -40°C ~ 85°C | 75% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
PTM2-24-S5-SDC-DC, ISOLATED, 2 W, 21.6~26.4 |
31 |
|
![]() Datasheet |
PTM2-S (2W) | 7-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 21.6V | 26.4V | 5V | - | - | - | 400mA | 2 W | 6 kV | ITE (Commercial), Medical | - | -40°C ~ 95°C (With Derating) | 81% | - | - | Through Hole | - | - | CE, cURus, UKCA | 60601-1; 62368-1 |
![]() |
REM2-053.3SDC DC CONVERTER 3.3V 2W |
30 |
|
![]() Datasheet |
MEDLINE REM2 (2W) | 8-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 4.5V | 5.5V | 3.3V | - | - | - | 606mA | 2 W | 5.2 kV | ITE (Commercial), Medical | OCP | -40°C ~ 95°C (With Derating) | 77% | - | - | Through Hole | - | - | CB, cURus | - |
![]() |
REM2-1505SDC DC CONVERTER 5V 2W |
10 |
|
![]() Datasheet |
MEDLINE REM2 (2W) | 8-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 13.5V | 16.5V | 5V | - | - | - | 400mA | 2 W | 5.2 kV | ITE (Commercial), Medical | OCP | -40°C ~ 95°C (With Derating) | 79% | - | - | Through Hole | - | - | CB, cURus | - |
![]() |
MDD06G-05DC DC CONVERTER +/-5V 3W |
47 |
|
![]() Datasheet |
MDD06 (6W) | 24-DIP Module, 6 Leads | Bulk | Active | Isolated Module | 2 | 18V | 75V | 5V | -5V | - | - | 600mA | 3 W | 6 kV | Medical | - | -40°C ~ 90°C (With Derating) | 80% | - | - | Through Hole | - | - | CE, EAC, UKCA | 60601-1 |
![]() |
MDD06F-15DC DC CONVERTER +/-15V 6W |
33 |
|
![]() Datasheet |
MDD06 (6W) | 24-DIP Module, 6 Leads | Bulk | Active | Isolated Module | 2 | 9V | 36V | 15V | -15V | - | - | 200mA, 200mA | 6 W | 6 kV | Medical | - | -40°C ~ 90°C (With Derating) | 82% | - | - | Through Hole | - | - | CE, EAC, UKCA | 60601-1 |
![]() |
MDD06F-12DC DC CONVERTER +/-12V 6W |
7 |
|
- |
MDD06 (6W) | 24-DIP Module, 6 Leads | Bulk | Active | Isolated Module | 2 | 9V | 36V | 12V | -12V | - | - | 250mA, 250mA | 6 W | 6 kV | Medical | - | -40°C ~ 90°C (With Derating) | 81% | - | - | Through Hole | - | - | CE, EAC, UKCA | 60601-1 |
|
RW2-2405D/SMDDC DC CONVERTER +/-5V 2W |
76 |
|
![]() Datasheet |
ECONOLINE RW2 (2W) | 16-SMD Module, 6 Leads | Tube | Active | Isolated Module | 2 | 18V | 36V | 5V | -5V | - | - | 200mA, 200mA | 2 W | 1 kV | ITE (Commercial), Medical | SCP | -40°C ~ 85°C | 78% | - | - | Surface Mount | - | - | - | - |
|
RW2-2415D/SMDDC DC CONVERTER +/-15V 2W |
43 |
|
![]() Datasheet |
ECONOLINE RW2 (2W) | 16-SMD Module, 6 Leads | Tube | Active | Isolated Module | 2 | 18V | 36V | 15V | -15V | - | - | 67mA, 67mA | 2 W | 1 kV | ITE (Commercial), Medical | SCP | -40°C ~ 85°C | 83% | - | - | Surface Mount | - | - | - | - |
![]() |
RS3-2415D/H3DC DC CONVERTER +/-15V 3W |
18 |
|
![]() Datasheet |
ECONOLINE RS3 (3W) | 8-SIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 18V | 36V | 15V | -15V | - | - | 100mA, 100mA | 3 W | 3 kV | ITE (Commercial), Medical | Remote On/Off, SCP | -40°C ~ 71°C | 83% | - | - | Through Hole | - | Enable, Active Low | - | - |