Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Features | Termination Style | Operating Temperature | Must Operate Voltage | Must Release Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
3RT20261AB001AA0CONTACTOR S0 25A 24VAC 1NO/1NC S |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 24VAC | 3PST-NO (3 Form A) | 25 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 19.2 VAC | - |
![]() |
3RT20262AL201AA0CONTACTOR.AC3:11KW 1NO+1NC 230V |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 230VAC | 3PST-NO (3 Form A) | 25 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 195.5 VAC | - |
![]() |
LP2K0610BD3REVERS CONT 6A AC3 2.2KW 24VDC L |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 6 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 50°C | 19.2 VDC | 2.4 VDC |
![]() |
LP2K0601BD3REVERS CONT 6A AC3 2.2KW 24VDC L |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 6 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 50°C | 19.2 VDC | 2.4 VDC |
![]() |
LC2K0901F72REVERSING CONTACTOR |
0 |
|
![]() Datasheet |
TeSys | Box | Active | Chassis Mount, DIN Rail | 110VAC | 3PST-NO (3 Form A) | 9 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 50°C | 88 VAC | 22 VAC |
![]() |
3RT20181AM210UA0CONTACTOR S00 16A 208VAC 1NO SCR |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 208VAC | 3PST-NO (3 Form A) | 22 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 176.8 VAC | - |
![]() |
3RT20181AV610UA0CONTACTOR. 5HP 460/575V.1NO. 480 |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 480VAC | 3PST-NO (3 Form A) | 22 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -25°C ~ 60°C | 408 VAC | - |
![]() |
CC75LD12RLY CONT 3P 12V DC 2NO/2NC |
0 |
|
![]() Datasheet |
CC | Box | Active | Chassis Mount, DIN Rail | 12VDC | 3PST-NO (3 Form A) | 75 A | 690VAC - Max | Auxiliary Contacts | Box Lug | -5°C ~ 60°C | 8.4 VDC | 1.2 VDC |
![]() |
CC75LD24RLY CONT 3P 24V DC 2NO/2NC |
0 |
|
![]() Datasheet |
CC | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 75 A | 690VAC - Max | Auxiliary Contacts | Box Lug | -5°C ~ 60°C | 16.8 VDC | 2.4 VDC |
![]() |
3RH21402XF400LA2AUX. RAIL CONTACTOR.4NO.72-125VD |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 72 ~ 125VDC | 4PST-NO (4 Form A) | 10 A | 690VAC - Max | Auxiliary Contacts | Spring Terminal | -40°C ~ 70°C | - | - |
![]() |
3RH21312XF400LA2AUX. RAIL CONT..3NO.1NC.72-125VD |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 72 ~ 125VDC | 4PST-3NO/1NC (3 Form A, 1 Form B) | 10 A | 690VAC - Max | Auxiliary Contacts | Spring Terminal | -40°C ~ 70°C | - | - |
![]() |
LC1D126SLS207CONTACTOR TESYS LC1D 3P AC3 440V |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 72VDC | 3PST-NO (3 Form A) | 12 A | 690VAC - Max | Auxiliary Contacts, Suppressor | Box Lug | - | 50.4 VDC | 7.2 VDC |
![]() |
LC1D126BLS207CONTACTOR TESYS LC1D 3P AC3 440V |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 24VDC | 3PST-NO (3 Form A) | 12 A | 690VAC - Max | Auxiliary Contacts, Suppressor | Box Lug | - | 16.8 VDC | 2.4 VDC |
![]() |
LC1D183G7TESYS CONTACTOR |
0 |
|
![]() Datasheet |
TeSys | Box | Active | Chassis Mount, DIN Rail | 120VAC | 3PST-NO (3 Form A) | 18 A | 690VAC, 300VDC - Max | Auxiliary Contacts | Spring Terminal | -40°C ~ 70°C | 96 VAC | 36 VAC |
![]() |
P40P42D12P1-24RELAY CONTACTOR 3PST 40A 24V |
0 |
|
![]() Datasheet |
P40 | Bulk | Obsolete | Chassis Mount | 24VDC | 3PST-NO (DM) (3 Form X) | 40 A | 600VAC - Max | - | Screw Terminal, Quick Connect - 0.250" (6.3mm) | -55°C ~ 65°C | 18 VDC | - |
![]() |
LC1D188M7TESYS 4P CTR 32A AC1 2NO 2NC 220 |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 220VAC | 4PST-NO (4 Form A) | 32 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 176 VAC | 66 VAC |
![]() |
LC1D188E7TESYS 4P CTR 32A AC-1 2NO 2NC 48 |
0 |
|
- |
TeSys | Box | Active | Chassis Mount, DIN Rail | 48VAC | 4PST-2NO/2NC (2 Form A, 2 Form B) | 32 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 38.4 VAC | 14.4 VAC |
![]() |
3RH21221KM400LA4CONT RELAY FOR RAILWAY,2NC+1NC, |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 220VDC | 3PST-NC (3 Form B) | 10 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 154 VDC | - |
![]() |
3RH21222KF400LA0CONT RELAY F RAILW 2NO+1NC DC 11 |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 110VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 10 A | 690VAC - Max | Auxiliary Contacts | Spring Terminal | -40°C ~ 70°C | 77 VDC | - |
![]() |
3RH21221KF400LA4CONT RELAY FOR RAILWAY,2NO+1NC, |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Chassis Mount, DIN Rail | 110VDC | 3PST-2NO/1NC (2 Form A, 1 Form B) | 10 A | 690VAC - Max | Auxiliary Contacts | Screw Terminal | -40°C ~ 70°C | 77 VDC | - |