Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CUS250M-15/JAC/DC CONVERTER 15V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS250M (250W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 15V | - | - | - | - | - | 16.66 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.56" H (101.6mm x 50.8mm x 39.5mm) |
![]() |
MS924AC/DC CONVERTER 24V 43W TDK-Lambda |
0 |
|
![]() Datasheet |
MS | Bulk | Obsolete | Enclosed | 1 | 85 ~ 132 VAC | 24V | - | - | - | - | - | 1.8 A | - | - | - | - | - | 43W | ITE (Commercial) | 2 kV | -10°C ~ 71°C (With Derating) | Adjustable Output, DC Input Capable, Remote On/Off, Universal Input | Chassis Mount | 6.30" L x 3.82" W x 1.69" H (160.0mm x 97.0mm x 43.0mm) |
![]() |
CUS250M-36/AAC/DC CONVERTER 36V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS250M (250W) | Bulk | Active | Enclosed | 1 | 80 ~ 264 VAC | 36V | - | - | - | - | - | 6.94 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.69" H (119.2mm x 64.0mm x 43.0mm) |
![]() |
CUS250M-28/AAC/DC CONVERTER 28V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS250M (250W) | Bulk | Active | Enclosed | 1 | 80 ~ 264 VAC | 28V | - | - | - | - | - | 8.92 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.69" H (119.2mm x 64.0mm x 43.0mm) |
![]() |
CUS250M-18/AAC/DC CONVERTER 18V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS250M (250W) | Bulk | Active | Enclosed | 1 | 80 ~ 264 VAC | 18V | - | - | - | - | - | 13.88 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.69" H (119.2mm x 64.0mm x 43.0mm) |
![]() |
CUS250M-15/AAC/DC CONVERTER 15V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS250M (250W) | Bulk | Active | Enclosed | 1 | 80 ~ 264 VAC | 15V | - | - | - | - | - | 16.66 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.69" H (119.2mm x 64.0mm x 43.0mm) |
![]() |
CUS250M-48/AAC/DC CONVERTER 48V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS250M (250W) | Bulk | Active | Enclosed | 1 | 80 ~ 264 VAC | 48V | - | - | - | - | - | 5.2 A | - | - | - | - | - | 250W | Household Appliances, ITE (Commercial), Laboratory, Medical | 4 kV | -20°C ~ 85°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | 4.69" L x 2.52" W x 1.69" H (119.2mm x 64.0mm x 43.0mm) |
![]() |
CUS400M-12/UAC/DC CONVERTER 12V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS400M (400W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 20.83 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.61" H (142.0mm x 90.0mm x 41.0mm) |
![]() |
CUS400M-15/UAC/DC CONVERTER 15V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS400M (400W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 16.67 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.61" H (142.0mm x 90.0mm x 41.0mm) |
![]() |
CUS400M-19/UAC/DC CONVERTER 19V 250W TDK-Lambda |
0 |
|
![]() Datasheet |
CUS400M (400W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 19V | - | - | - | - | - | 13.16 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.61" H (142.0mm x 90.0mm x 41.0mm) |